Overview of Shock Absorbers

Quote

Series 50/70
Series 60
Series 40
Series 30
Series 20
Series 10

Arm Specification

Home

Engineering Data Sheet
POWERED SWINGING LOAD

RECOMMEND STANDARD SERIES 50

Let W = 500#, W1=55#, H=6.7", D=10" F=100#, T=955 inch lbs., Ø=1.047 radians.

E = W x H + F x D
E = (500)(6.7) + (100)(10)
E = 4350 IN. LB. ENERGY

IF THE INPUT POWER IS TORQUE THRU AN ANGLE:

IF THE WEIGHT OF THE ARM (W1) IS GREATER THAN 10% OF W:

E = W x H + T x Ø
E = (500)(6.7) + (955)(1.047)
E = 4350 IN. LBS. ENERGY

E = (W x W1)x H + T x Ø
E = (500 + 55) (6.7) + (955) (1.047)
E = 4718.5 IN. LBS. ENERGY

SYMBOLS

E

= Energy ........................... Inch Pounds
W = Weight............................ Pounds
V = Contact Velocity ............ FT/Sec.

Note: Contact Engineering Department is contact velocity exceeds 20 ft./sec.

H = Total Vertical Distance... Inches
t = Deceleration Time........... Sec.
D = Shock Absorber Stroke... Inches
G = Deceleration Force.......... Pounds
F = Driving Force................... Pounds
T = Propelling Torque ............ Inch Pounds
Ø = Deceleration Angle........... Radians
Note: 1 Radian = 57.3 Degrees

Back to Hydraulic Products Engineering Data Main Page


Modern Industries, Inc., Corporate Offices
613 West 11th ST., Erie, PA 16512
PH: (814) 455-8061 Fax: (814) 453-4382